Fixing Socket with Waved End

Fixing Socket with Waved End

Lifting and Fixing Tools

Fixing Socket with Waved End
ReferenceThread x LE
[mm]
F
[daN]
637106030EZ0M6 x 301080
637106050EZ0M6 x 5030150
637108040EZ0M8 x 4015200
637108050EZ0M8 x 5020250
637110040EZ0M10 x 4015300
637110050EZ0M10 x 5020350
637112060EZ0M12 x 6025500
637116100EZ0M16 x 100451000
637120100EZ0M20 x 100651250
Fixing Socket with Waved End
ReferenceThread x LCN
[mm]
CV
[mm]
S
[mm]
H
[mm]
637106030EZ0M6 x 3045609055
637106050EZ0M6 x 507510015075
637108040EZ0M8 x 40608012065
637108050EZ0M8 x 507510015075
637110040EZ0M10 x 40608012065
637110050EZ0M10 x 507510015075
637112060EZ0M12 x 609012018085
637116100EZ0M16 x 100150200300125
637120100EZ0M20 x 100150200300125

Fixing sockets with waved end are self-anchoring sockets.

Fixing sockets must not be used for lifting but exclusively for fixing. Fixing sockets are electro-galvanised bichromated.

Permissible loads F are defined for concrete compressive strength of 25 MPa.

To avoid premature failure of the socket by blow-out of the concrete, the socket has to be placed with minimum distances, from the edge and between sockets.
For straight pulling N, the minimum edge distance is CN and the minimum distance between 2 sockets is S. For shear force V, the minimum edge distance is CV and the minimum distance between 2 sockets is S. The minimum thickness of the panel should be H (minimum concrete cover of 25 mm). When the force is a combination of shear force V and straight pull N, the permissible load F should respect the following formula:

√(V2+N2) ≤ perm. F

Fixing sockets must be used with metric thread screw. They must be screwed on at least one time the diameter and no more than E.